Menu Close

Clima Sensor US

Make:  Thies    Model:  4.9200.00.001
✅ Compact Weather Station, easy mounting, GPS receiver, all in one weather station.
✅ Measurand: Wind Speed, Wind Direction, Precipitation, Temperature, Rel. Humidity, Brightness, Twilight, Radiation, Air pressure
✅ Signal Output:RS485 / RS422
Compare

The CLIMA SENSOR US is used for acquisition of the most important meteorological parameters. Depending on the development level the device supplies measured data for:

  • wind speed and direction, averaging acc. to WMO-recommendations
  • air temperature
  • relative humidity
  • barometric air pressure
  • precipitation
  • brightness

The compact design, simple mounting and different options for data output permit operation with numerous applications.
Wind speed and wind direction are determined by acquiring 2-dimensional horizontal components of ultrasonic measurement paths positioned at right angles in relation to each other. The speed of sound can be additionally used to calculate and output the acoustic virtual temperature. The ultrasonic measurement principle allows inertia-free measurement of gusts and peak values.
Air temperature and relative humidity are measured via a built-in precision combination sensor, which is equipped with a weather and radiation shield. Barometric air pressure is measured with a MEMs (micro-electro-mechanical system) sensor, based on piezoresistive technology.
Measurement of the precipitation intensity are contactless using a signal reflected with a Doppler radar. When calculating, the intensity captured for the last minute is extrapolated to an output for one hour. The type of precipitation can roughly be determined from the measured values of rainfall speed, intensity, temperature and humidity.
Brightness is captured by 4 photo sensors with spectral sensitivity curve. The direction of the light source is calculated using the prevailing intensity conditions. The logarithmic intensity characteristic of the photo sensors allows light intensities to be measured and output in a wide range between 1 – 150,000 lux.
A GPS receiver is used for the determination of position and as a real-time source.
Additionally, it is used to calculate the current position of the sun.
Position, time and position of the sun are provided via the RS485 / RS422 interfaces.
A RS485/422 interface is available for serial communication.
It can be operated in full or half duplex mode. Predefined data telegrams are available for outputting measured values (e.g., VD, VDT, NMEA, etc.). A Modbus RTU protocol is additionally implemented for extended standardised communication. The device can be switched to Modbus RTU mode with the relevant command.
The CLIMA SENSOR US is equipped with a built-in heating system.

Applications:This instrument has a GPS receiver. It serves for the determination of position and time, the sun position is additionally calculated herefrom. Position, Time, and sun position are transmitted serially.The compact construction, easy mounting, and diverse options of data output are the basis for the use in several fields:

  • Building control system
  • Traffic engineering
  • Meteorology
  • Energy supply
  • Ecological monitoring

Parameters Measured:

  • Wind Speed
  • Wind Direction
  • Precipitation
  • Brightness
  • Temperature
  • Humidity
  • Pressure
Make

Thies Clima

Model

4.9200.00.001

General Specification

:-

Weight (Mass)

0.9 kg

Dimension

Ø 150 x 220 mm

Outputs

Data output digital: Protocol- MODBUS RTU ( preselected )
Data output analog: Output parameters- wind speed, wind direction, brightness, precipitation, rel. humidity, air temperature, air pressure , etc.

Power Supply

6 … 40V DC or 10 … 28 V AC / 1.2 W

Protection Level

IP 67

Wind speed

Measuring range: 0 … 60 m/s
ResolutionL: 0.1 m/s ( standard )
Accuracy: ±0.3 m/s rms ( < 5 m/s ), ±3 % rms ( 5 m/s … 60 m/s )

Wind direction

Measuring range 0 … 360 °
Resolution 1 ° , 0.1 ° in special telegrams
Accuracy ±2 ° WS > 2 m/s

Precipitation

Measuring range: 0.001 … 10 mm/min

Temperature

Measuring range: -40 … +80 °C
Accuracy: ±0,3 K ( @ 25 °C )

Relative Humidity

Measuring range: 0 … 100 % rel. h.
Accuracy: ± 1.8 % rel. h. ( 10 % … 90 % rel. H. )

Brightness

Measuring range: 0 … 150 kLux
Accuracy: 3 % of rel. measuring value

Twilight

Measuring range: 0 … 250 Lux
Accuracy: ±3 % of rel. measuring valuet

Air Pressure

Measuring range: 260 … 1260 hPa
Accuracy: ±0.25 hPa @ – 20 … +80 °C @ 800 … 1100 hPa, ±0.50 hPa @ – 20 … +80 °C @ 600 … 800 hPa, ±1.00 hPa @ – 50 … -20 °C @ 600 … 1100 hPa